MBS-GPS Novatel SSII & OEMV-1 PC/104 GPS Module User’s ManualCAGE Code 3DPE9ALL RIGHTS RESERVEDHowever, any part of this document may be reproduce
J7, EXT RS-232 Serial PortJ7 is a standard 16C850 128 byte FIFO serial port with the exception that it supports baud rates up to 921 kbaud1. DCD2. D
Figure 2Functional Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 31PPS Selection Logic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4 TTL Level 1PPS Inversion Logic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 5RS-232 Level 1PPS Output Inversion Logic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 61PPS Monitoring Schema. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RETURNING A PRODUCT FOR REPAIR Upon determining that repair services are required, the customer must:1. Obtain an RMA (Return Material Authorization)
WWW.MICROBEE-SYSTEMS.COM
NOTICE TO USER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PREFACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OEMV-1 3.3V GPS.Once the unit is configured and installed it is treated as three standard serial ports on the PC/104 stack. As an example, if the Data
921,600 baud.The Novatel SSII-5Hz supports a maximum of 19,200 baud. The OEVM-1 supports up to 921,600 baud.Environmental -35° to 70° C operating.-40
Address Selection Rotary SwitchesFor flexibility with most SW and Development libraries this unit will support any valid address between 0x000-0x007 an
Un-Inverted, I = Inverted. RTS1 Inverts or un-inverts the RS-232 1PPS signal output. Bit set = invert. DTR0 Inverts or un-inverts the TTL 1PPS sign
NOTEIf AUX PPS is selected then the these features will work upon the AUX signal instead of the GPS signal. The AUX is primarily used for software de
PPS IO Connector, J6 Terminal BlockJ6 is the IO for the 1PP signal. The pinouts are as follows:J6.11PPS Output. This represents the 1PPS output in R